Sunscreen filter photostability: what is it and how do you measure it?

The photostability of a UV filter is its ability to keep absorbing UV radiation during sun exposure. It is measured mainly in vitro, by comparing the absorbance spectrum of a product film before and after a controlled UV dose, and by chromatographic assay of the filters remaining. A poorly photostable product can lose a significant share of its protection over the course of exposure, even if its initial SPF is high.

What is sunscreen filter photostability?

An organic filter absorbs UV energy and then dissipates it, usually as heat, before returning to its initial state. When this cycle does not complete properly, the molecule changes: it isomerises, breaks down or reacts with other ingredients. It then absorbs less, or at different wavelengths, and protection decreases.

Photostability does not depend on the filter alone. It also depends on the whole formula: how filters are combined, the nature of the emollients and the presence of photostabilisers or antioxidants. A filter known to be unstable can become acceptable in a well-designed formula, and the reverse is also true. This is why photostability data are most meaningful when generated on the final formula, rather than on raw materials tested in isolation.

Which filters raise photostability issues?

The best-known case is avobenzone (butyl methoxydibenzoylmethane), a widely used UVA filter that is inherently photounstable. When combined with octinoxate (ethylhexyl methoxycinnamate), it degrades even further, as the two molecules react with each other under irradiation.

To stabilise it, formulators pair it with photostabilising filters or ingredients, such as octocrylene or bemotrizinol, or with dedicated molecules that dissipate absorbed energy. Mineral filters (titanium dioxide, zinc oxide) are photostable in themselves, but their photocatalytic activity generally calls for a surface coating, whose integrity must also be checked.

How is photostability measured in vitro?

The most widely used method is spectrophotometric. It follows the same principle as in vitro UVA protection tests, with measurements taken before and after irradiation.

The spectrophotometric protocol

  • Preparation: the product is spread at a defined rate onto roughened PMMA plates and left to dry.
  • Initial measurement: the absorbance spectrum is recorded between 290 and 400 nm.
  • Irradiation: the plates are exposed to a solar simulator at one or more doses, expressed in joules per cm² or in minimal erythemal doses.
  • Final measurement: the spectrum is recorded again and compared with the initial one.
  • Interpretation: the share of absorbance retained is calculated across the whole spectrum or by range (UVB, short UVA, long UVA), along with changes in in vitro SPF, UVA-PF and critical wavelength.

A common indicator is the area under the curve index, the ratio between the area after and before irradiation. In the literature, a product is often considered photostable above a threshold of around 0.80, but this threshold is not set by any standard.

Chromatographic assay

Liquid chromatography (HPLC) quantifies each filter before and after irradiation. It shows which filter degrades and to what extent, whereas spectrophotometry only gives an overall result. Coupled with mass spectrometry, it can also identify the photoproducts formed.

Is photostability taken into account in regulatory tests?

There is no ISO standard dedicated solely to photostability. It is, however, built into several regulatory tests through a pre-irradiation step.

ISO 24443, the reference method for UVA-PF in Europe, applies a UV dose proportional to the initial UVA-PF before the final measurement, so a product that degrades shows a lower UVA-PF. The FDA broad spectrum test also includes pre-irradiation before critical wavelength is measured. In vivo SPF, by contrast, only reflects photostability indirectly, through the doses received during irradiation.

Summary of photostability evaluation methods

MethodWhat it measuresStrengthsLimitationsTypical use
Spectrophotometry before and after irradiationAbsorbance retained, changes in in vitro SPF, UVA-PF and critical wavelengthFast, close to film conditions on skinOverall result, no breakdown by filterScreening and formula selection
ISO 24443 pre-irradiationUVA-PF after exposureBuilt into a regulatory testSingle dose, no kinetic studyUVA claims in Europe
FDA test pre-irradiationCritical wavelength after exposureRequired for the US marketSingle indicator“Broad spectrum” labelling
HPLC before and after irradiationAmount of each filter remainingIdentifies the degrading filterLonger, extraction requiredDevelopment, technical file
HPLC coupled with mass spectrometryNature of photoproductsInput for safety assessmentSpecific analytical expertiseSafety file

These methods complement each other: spectrophotometry guides formula choices, while chromatography explains the results and documents the file. To find laboratories that run photostability studies and UV filter assays, you can search for a provider on Skinobs.

Why does photostability also matter for safety?

A filter that degrades does not just lose efficacy. The photoproducts formed can be more reactive than the parent molecule and promote the formation of reactive oxygen species or photosensitisation reactions.

The safety assessment of a sun care product may therefore include phototoxicity tests, such as the in vitro 3T3 NRU test described in OECD Test Guideline 432, and photosensitisation tests. These studies complement photostability measurement, which shows how much of which photoproducts may form on the skin surface.

How do you build photostability into a sun care project?

Photostability should be addressed from the very first formulas, well before claim tests. A few steps help avoid unpleasant surprises late in development.

  • Screen early: compare several prototypes by spectrophotometry before and after irradiation, at doses representative of real exposure.
  • Understand the gaps: if absorbance drops, use HPLC assay to find out which filter is degrading.
  • Retest after every change: switching an emollient or a filter supplier can alter the formula’s photostability.
  • Anticipate safety: document photoproducts when the formula combines filters known to react with each other.

The irradiation dose deserves particular attention. A dose that is too low makes almost any formula look stable, while a very high dose can penalise products that perform well in real use. Testing at several doses, expressed in a way that relates to realistic sun exposure, gives a more useful picture than a single endpoint and makes it easier to compare prototypes or competitor products on a consistent basis.

FAQ

Is a high-SPF product necessarily photostable?

No. In vivo SPF reflects protection under test conditions, with limited doses. A product can show a high SPF and still lose part of its protection, particularly in the UVA range, during prolonged exposure.

Are mineral filters always photostable?

Titanium dioxide and zinc oxide do not degrade under UV. Their photocatalytic activity does, however, require a coating, whose stability in the formula must be checked.

Is there a regulatory photostability threshold?

No threshold is set as such. Photostability is taken into account indirectly through the pre-irradiation steps of the ISO 24443 and FDA tests, which govern UVA and broad spectrum claims.

Which method should you choose to document a technical file?

Combining spectrophotometry with HPLC assay is the most complete approach: the first measures the overall effect on protection, the second identifies the filters involved.

Find a laboratory for your photostability studies